Preliminary treatment of landfill leachate by hydrodynamic cavitation supported by Fenton process
- MOJ Ecology & Environmental Sciences
-
Mehtap Dursun,1 Bülent Keskinler,1 Nihal Bektaş,1 Ergün Yıldız2
Abstract
Hydrodynamic cavitation as an effective and environmentally friendly method of treating wastewater. Massive amounts of energy may be released into the surrounding liquid during hydrodynamic cavitation, resulting in mechanical , chemical and thermal impacts. Bacteria and organic materials in sewage can be broken down by these circumstances. Furthermore, a coupling effect may be created by combining hydrodynamic cavitation with other water treatment techniques.
In this study it is aim to investigate and improve the hydrodynamic cavitation (HDC) process supported by Fenton process for the pretreatment of landfill leachate. In the second phase of the study, the effectiveness of the hydrodynamic cavitation process was investigated in conjunction with the Fenton process. The parameters such as the number of cavitation events, pH, and temperature were evaluated. The effluent was characterized and monitored for COD measurements. The consequences of operational variables such H2O2, Fe+2 , and pH values were investigated to determine the optimal Fenton oxidation process parameters. The findings of the experiment showed that pH values were ideal for Fenton oxidation of 3.5-4.5, 30 mM H2O2, and 5 mM Fe+2.
A combined treatment process of Fe+2+H2O2, HDC + Fenton, and Cavitation alone were conducted for the treatment of landfill leachate. The results showed that the removal rates of chemical oxygen demand (COD) for the combined processes were 32.85%, 44.28%, and 7%, respectively. Temperature, pH, and the number of cavitation events were among the parameters that were assessed. The effluent was measured for COD and was characterized.
Keywords
pre-treatment, leachate, hydrodynamic cavitation, Fenton process